Welcome to WINTPOWER

AC Alternator Brushless Alternator 100% Copper Alternator China Generator

AC Alternator Brushless Alternator 100% Copper Alternator China Generator

Quick Details:

China AC Alternator
China copy Alternator
Copy Stamford alternator
Alternator China made
AC Brushless atlernator
100% copper alternator


Product Detail

AC Brushless atlernator

Product Tags

SPECIFICATIONS & OPTIONS STANDARDS “WINTPOWER industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request.”

VOLTAGE REGULATORS SX460 AVR – STANDARD “With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit.”

AS440 AVR
“With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS440 will support a range of electronic accessories, including a ‘droop’ Current Transformer (CT) to permit parallel operation with other ac generators.”

MX341 AVR
“This sophisticated AVR is incorporated into the WINTPOWER Permanent Magnet Generator (PMG) control system. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds. An engine relief load acceptance feature can enable full load to be applied to the generator in a single step. If three-phase sensing is required with the PMG system the MX321 AVR must be used. We recommend three-phase sensing for applications with greatly unbalanced or highly non-linear loads.”

MX321 AVR

“The most sophisticated of all our AVRs combines all the features of the MX341 with, additionally, three-phase rms sensing, for improved regulation and performance. Over voltage protection is built-in and short circuit current level adjustments is an optional facility.”

Windings & Electrical Performance
“All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.”

Terminals & Terminal Box
“Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers’ wiring and gland arrangements. It has removable panels for easy access.”

Shaft & Keys
“All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key.”

INSULATION/IMPREGNATION
“The insulation system is class ‘H’. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components.”

Quality Assurance
“Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001.”

“The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria ‘B’ of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%.”

“NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range.”


  • Previous:
  • Next:

  • AC Brushless atlernator,3Ph, 0.8PF, IP23, H insulation.
    MODEL 3Phase/50Hz/340-415V 3Phase/60Hz/220-440V-480V
    Standby Power Continuous power Standby Power Continuous power
    KVA KW KVA KW KVA KW KVA KW
    WT184E 22 18 20 16 25 21 23 18
    WT184F 30 24 27 22 34 28 31 25
    WT184J 44 35 40 32 51 40 46 37
    WT224D 55 44 50 40 63 51 57 46
    WT224E 70 56 63 50 80 64 72 57
    WT224F 88 70 80 64 101 80 92 74
    WT274C 110 88 100 80 126 101 115 92
    WT274D 125 100 113 90 144 115 130 103
    WT274E 150 120 137.5 110 172 138 158 126
    WT274F 165 132 150 120 190 152 172 138
    WT274G 200 160 180 144 230 184 207 166
    WT274H 220 176 200 160 253 202 230 184
    WT274J 250 200 230 184 287 230 264 211
    WT274K 275 220 250 200 316 253 287 230
    WT444D 300 240 275 220 345 276 316 253
    WT444E 350 280 313 250 402 322 360 287
    WT444F 413 330 375 300 475 379 431 345
    WT544C 500 400 450 360 575 460 517 414
    WT544D 550 440 500 400 632 506 575 460
    WT544E 650 520 575 460 747 598 661 529
    WT544F 715 570 650 520 822 655 747 598
    WT544G 825 660 750 600 948 759 862 690
    WT634C 880 704 800 640 1011 809 920 736
    WT634D 1000 800 910 728 1149 920 1046 837
    WT634E 1100 880 1000 800 1264 1011 1149 920
    WT634F 1250 1000 1100 900 1437 1149 1264 1034
    WT634G 1375 1100 1250 1000 1580 1264 1437 1149
    WT634H 1512 1210 1375 1100 1738 1391 1580 1264
    WT634J 1650 1320 1500 1200 1897 1517 1724 1379
    WT734C 1875 1500 1700 1360 2155 1724 1954 1563
    WT734D 2063 1650 1875 1500 2371 1897 2155 1724
    WT734E 2250 1800 2000 1600 2586 2069 2299 1839
    WT734H 2500 2000 2250 1800 2874 2299 2586 2069